Rheem Furnace Error Code 57 – Meaning, Causes & Fix
Rheem furnace error code 57 is an inducer motor fault that appears on Rheem Prestige Series and Classic Plus communicating gas furnaces when the control board detects that the variable-speed inducer motor has failed to reach its commanded speed or has stopped unexpectedly during operation. On Rheem communicating systems (paired with the EcoNet thermostat or a compatible control), error code 57 is displayed directly on the thermostat or furnace diagnostic interface. On non-communicating Rheem models, inducer faults typically manifest as a blink code on the control board LED. Code 57 specifically targets the inducer's ECM (electronically commutated motor) communication fault — the motor is not reporting back its speed or operational status to the control board. This guide covers every cause and troubleshooting step for Rheem error code 57. For related HVAC furnace faults, see our Carrier Furnace Error Code 31 guide, Lennox Furnace Error Code 201 guide, and Goodman Furnace Pressure Switch Stuck Open guide.
What it means
The variable-speed inducer motor has not reached its commanded speed, has stalled, or has stopped communicating with the control board. The furnace cannot safely operate without confirmed inducer function.
Severity
HighCan you fix it yourself?
Limited — checking wiring connections and power cycling are safe DIY steps. ECM inducer motor or control board replacement requires a licensed HVAC technician.
Call a technician when
Contact a licensed HVAC technician if error 57 persists after a power cycle and basic wiring inspection.
What Does 57 Mean?
Rheem Prestige and Classic Plus furnaces use an ECM (electronically commutated motor) for the combustion air inducer. Unlike older single-speed PSC motors, an ECM inducer communicates with the control board in real time, reporting its RPM and operational status.
Error code 57 is a motor communication or performance fault:
1. ECM motor communication failure: The motor's internal control module has stopped responding to the furnace control board's commands or status requests. 2. Inducer motor stall or overload: The motor started but stalled due to a mechanical obstruction, bearing failure, or over-temperature condition. 3. Low supply voltage: The inducer's ECM module requires stable line voltage. A voltage sag or interruption causes the motor to fault and report error 57. 4. Failed ECM motor module: The control module within the ECM motor (a replaceable component on some motor types) has failed. 5. Wiring harness fault: A loose, corroded, or broken connection in the motor's multi-pin wiring harness disrupts the communication signal. 6. Control board fault: The furnace's main control board has a failed relay or communication circuit that misreports the motor status.
For pressure switch faults often associated with inducer issues, see Carrier Furnace Error Code 31 and Goodman Furnace Pressure Switch Stuck Open. The Lennox Furnace Error Code 201 describes an ignition fault that can follow if the inducer issue is not resolved.
What Causes This Error?
- ECM inducer motor control module failed — motor not communicating with control board
- Inducer motor bearing seized or stalling under load
- Low or unstable line voltage to the inducer motor ECM module
- Loose, corroded, or damaged multi-pin wiring harness connector at the inducer motor
- Blocked flue or intake creating excessive back-pressure against the inducer
- Inducer motor overheating due to extended operation in high ambient temperatures
- Furnace control board relay or motor communication circuit failed
- Foreign object (debris, insulation) lodged in the inducer wheel causing stall
How to Fix 57
- 1
Power cycle the furnace. Turn the furnace off at the power switch. Wait 60 seconds. Power back on. An ECM motor fault can sometimes be a transient communication error that clears on reinitialization. On a Rheem EcoNet-connected system, also clear the error code on the thermostat: navigate to System > Diagnostics > Clear Faults. Initiate a new heat call and observe whether the inducer starts normally and the furnace progresses through the startup sequence.
- 2
Listen to the inducer on startup. With the furnace powered on and a heat call active, stand near the furnace and listen during the first 30–60 seconds. The inducer should start and build to a steady, smooth-running sound within 15–20 seconds. If you hear the inducer attempt to start, stutter, or make a grinding or buzzing sound before stopping, this confirms a mechanical or electrical motor fault. If there is no sound at all from the inducer, the motor, its power supply, or the wiring connection has failed.
- 3
Inspect the inducer motor wiring harness. With the furnace powered off, open the cabinet and locate the inducer motor — a cylindrical motor mounted on the side of the inducer housing at the top of the furnace heat exchanger section. Trace the multi-pin wiring harness from the motor to the control board. Check each connector for: loose fit (connectors should click firmly into place), corrosion (green or white oxidation on pins), and physical damage (burned insulation, broken pins). Reconnect any loose connectors firmly.
- 4
Check the inducer wheel for obstructions. With the furnace powered off, locate the inducer housing (the scroll-shaped housing the motor attaches to). If accessible, carefully check for debris, insulation fragments, or foreign objects inside the wheel housing that could cause the impeller to jam. A small fragment of insulation from nearby ductwork is a common cause of inducer stalls on Rheem furnaces installed in attics or unconditioned spaces.
- 5
Check line voltage at the furnace. Use a multimeter to verify that the furnace is receiving 115–125V AC at the furnace power switch. Low voltage (below 105V) can cause ECM motors to fault and report communication errors. If voltage is consistently low, contact an electrician to address the supply circuit.
- 6
Verify flue and intake are clear. A blocked flue creates excessive back-pressure against the inducer, which can cause it to overload and stall. Inspect the PVC exhaust and intake pipes outside the building and clear any obstructions. On Rheem two-stage and modulating furnaces, the inducer modulates its speed based on the heating stage — a partial blockage may only cause error 57 on high-fire calls.
When to Call a Professional
Rheem error code 57 that persists after a power cycle, wiring inspection, and flue check indicates a failed ECM inducer motor or a faulty furnace control board. ECM inducer motor replacement is a professional repair — the motor must be matched exactly to the furnace model and requires HVAC training to install correctly. Contact Rheem support at rheem.com/support or your local Rheem Pro Partner dealer. ECM inducer motor replacement costs $400–$800 including labor. Rheem furnaces carry a 10-year parts warranty on registered units.
Can You Still Use the Device?
The Rheem furnace will not attempt ignition while error code 57 is active because safe inducer operation has not been confirmed. Do not attempt to bypass the inducer safety circuit. Operating a furnace without a functioning inducer is a carbon monoxide hazard. Resolve the fault before resuming heat.
See Also
Official Resources
Related Error Codes
Disclaimer: This article is for informational purposes only and does not constitute professional repair advice. CodeExplain is not affiliated with Rheem or any other brand mentioned. Always consult a qualified technician for complex repairs.