Bryant Furnace Error Code 33 – Meaning, Causes & Fix

BryantFurnaceUpdated 2026-07-08

Bryant furnace error code 33 is a limit circuit fault that appears on Bryant gas furnaces when the control board detects that one or more safety limit switches in the limit circuit have opened during furnace operation. Bryant furnaces (which share their platform with Carrier, as both brands are owned by Carrier Global) display error codes as blink sequences on the diagnostic LED visible through the furnace access panel window — code 33 appears as a 3-3 blink pattern. The limit circuit includes the high limit switch (primary overtemperature protection), the auxiliary limit switch, and the rollout switches. Any of these opening interrupts the limit circuit and triggers error 33. The most common cause is insufficient airflow across the heat exchanger due to a clogged air filter, blocked vents, or a failing blower motor. This guide covers every cause and fix for Bryant error code 33. For related HVAC limit and overtemperature faults, see our York Furnace Red Light Flashing 4 Times guide and our Carrier Furnace Error Code 31 guide.

Quick Answer

What it means

A safety limit switch in the furnace limit circuit has opened due to overtemperature, rollout, or excessive heat. The burners have been shut off as a safety measure.

Severity

High

Can you fix it yourself?

Partial — replacing the air filter and checking vents are safe DIY steps. A failed blower, tripped rollout switch, or cracked heat exchanger requires a licensed HVAC technician.

Call a technician when

Contact a licensed HVAC technician if code 33 persists after replacing the filter and clearing vents, or if the blower motor is not running at full speed.

What Does 33 Mean?

Bryant gas furnaces use a limit circuit — a series circuit connecting multiple safety switches — to monitor furnace operating temperatures. If any switch in this circuit opens (trips), the circuit breaks and the control board displays error 33 and shuts off the gas valve.

The limit circuit typically includes:

1. High limit switch: Monitors heat exchanger temperature. Trips when the plenum temperature exceeds the rated threshold (typically 195–200°F). 2. Auxiliary limit switch: A secondary overtemperature switch, often on the blower compartment or secondary heat exchanger. 3. Rollout switches: One or more rollout switches are mounted near the burners. They trip if flames roll out of the burner box (caused by heat exchanger cracks, blocked flue, or combustion air issues).

Why does the limit circuit open?

1. Restricted airflow: A clogged filter or blocked vents causes the heat exchanger to overheat, tripping the high limit switch. This is the most common cause. 2. Blower motor or capacitor failure: If the blower runs slowly or not at all, insufficient air moves across the heat exchanger. 3. Tripped rollout switch: A rollout switch that has tripped requires manual reset — it does not automatically reset. If a rollout switch has tripped, it must be investigated before resetting. 4. Cracked heat exchanger: Combustion gases escaping through a crack alter the temperature distribution and can trigger multiple limit switches. 5. Flue blockage: A blocked flue backs up combustion heat, elevating plenum temperatures.

This fault is closely related to the York Furnace Red Light Flashing 4 Times (high limit open) and the Rheem Furnace Error Code 57 (inducer fault leading to overtemperature).

What Causes This Error?

  • Severely clogged air filter restricting airflow over the heat exchanger
  • Supply or return vents closed, blocked, or covered
  • Blower motor failed or not running at full design speed
  • Blower run capacitor failed, causing sluggish motor performance
  • Rollout switch tripped due to flame rollout event
  • Cracked heat exchanger allowing combustion gas to affect temperature sensors
  • Blocked flue exhaust restricting combustion heat removal
  • Auxiliary limit switch fatigued or miscalibrated, tripping prematurely

How to Fix 33

  1. 1

    Confirm error code 33. Look through the diagnostic window on the Bryant furnace access panel. Count the blink pattern: 3 blinks, pause, 3 blinks, repeat. Confirm against the fault code chart on the inside of the access panel door — on Bryant furnaces, 3-3 should correspond to 'Limit Circuit Open.' Different Bryant models may have slight variations in fault code assignments.

  2. 2

    Replace the air filter. This is the first and most impactful step. Locate and remove the air filter. If it is gray, brown, or visibly clogged, it is the likely cause. Replace with a new filter of the correct size (MERV 8 or below for most Bryant residential furnaces). After replacing the filter, allow the furnace to cool for 30 minutes, then attempt a heat call. Many code 33 errors on Bryant furnaces are permanently resolved by a filter change alone.

  3. 3

    Check all vents and registers. Walk through the entire home and ensure every supply register (air out) and return grille (air in) is fully open and unobstructed by furniture, rugs, or stored items. On Bryant two-stage and variable-speed systems, even partial vent blockage can cause high limit trips during extended high-fire operation.

  4. 4

    Verify blower motor operation. Set the thermostat to Fan Only mode to test the blower independently. Listen and feel supply registers for strong, consistent airflow. If airflow is weak, the blower motor or run capacitor may be failing. A motor that hums without building speed, or does not start, has a failed run capacitor or motor winding fault. Do not continue running the furnace with a failing blower.

  5. 5

    Inspect for a tripped rollout switch. Open the furnace burner compartment access panel. Locate the rollout switch(es) — small disc-shaped components with a button on top, mounted near the burner manifold. If the button is popped out (not flush), the rollout switch has tripped and must be manually reset by pressing the button. However, a tripped rollout switch indicates a genuine flame rollout event — caused by a blocked flue, cracked heat exchanger, or combustion air issue — and must be investigated by a technician before resuming operation.

  6. 6

    Inspect the flue pipe. Go outside and visually inspect the furnace flue exhaust pipe. On PVC-flued 90%+ models, check both the exhaust and intake pipes for blockages — birds nests, ice, or debris. On metal-flued 80% models, inspect the visible flue sections for disconnected joints, visible damage, or blockage. A blocked flue causes combustion heat to back up into the furnace, overheating the heat exchanger and tripping the limit circuit.

When to Call a Professional

Bryant error code 33 that persists after replacing the filter, clearing vents, and verifying blower operation — or a tripped rollout switch — requires professional diagnosis. A tripped rollout switch, persistent high limit tripping, or suspected cracked heat exchanger are all serious safety issues requiring a licensed HVAC technician. Contact your local Bryant dealer or authorized HVAC contractor. Bryant dealers can be found at bryant.com/residential/find-a-dealer. High limit switch replacement costs $100–$250. Blower motor replacement costs $300–$600. Rollout switch investigation and repair costs $150–$400 depending on cause.

Can You Still Use the Device?

Do not continue to operate the Bryant furnace while code 33 is active or recurs repeatedly. The limit circuit is protecting the heat exchanger from catastrophic damage. Repeated overtemperature cycles accelerate heat exchanger fatigue and can cause cracking, creating a carbon monoxide risk. Resolve the airflow or mechanical fault completely before resuming heating.

Official Resources

Related Error Codes

Disclaimer: This article is for informational purposes only and does not constitute professional repair advice. CodeExplain is not affiliated with Bryant or any other brand mentioned. Always consult a qualified technician for complex repairs.